Check system logs for intrusion attempts, and ensure strong password policies. This message is displayed when event logging of a specific type is disabled by the user. This message is displayed when all event logging has been disabled by the user. When the event log is full, additional events are not written to the log.
Older events may be overwritten and lost. This message may also appear if the user disabled event logging. If the system event log fails to initialize, platform status and failure events are not captured. Some management software do not report platform exceptions. Reboot the management controller or iDRAC.
Cycle system input power. If problem persists call support. If the system event log failed to initialize platform status and failure events are not captured. Some management software will not report platform exceptions.
Re-configure system to minimum supported configuration. If issues persists, contact support. System policies or permissions may prevent the action from executing. If configured, the system does not execute the action on a platform event such as power down, cycle, interrupt, and send alert.
The time stamp on system event log events may not correlate to the system time. System setup displays the system boot order. The local video screen may also show additional information. IPMI sensor type code 1eh - offset 00h. Check system boot settings. Check if mass storage controller configuration settings are applicable. The disk in the drive is not formatted correctly or does not contain the necessary operating system files. The system has failed to boot to an operating system and needs the user to select a boot source.
Check the CMC network cables and network connections. Check that CMC firmware versions match. The chassis management controller CMC is not redundant. The current software version cannot decode this event. You may need to review this event using a tool which displays raw data such as Ipmitool with the -vvv option or Racadm with the -E option.
Update with the latest version. FlexAddress is not implemented in one of the versions of firmware. Please update the firmware. Check the fans. Check Fans. If multiple voltage exceptions occur consecutively the system may power down in fail-safe mode. Review system logs for power supply exceptions. Remove the processor module. Inspect processor socket for bent pins. Re-configure the system to minimum configuration, inspect and reinstall system cables. Re-seat the mezzanine card. Error Code.
System level current is less than the lower warning threshold. System level current is outside of the optimum range. System level current is outside of range. System level current is greater than the upper warning threshold. System level current is greater than the upper critical threshold. Chassis power level current is less than the lower warning threshold. Chassis power level current is outside of the optimum range. Chassis power level current is less than the lower critical threshold.
Chassis power level current is greater than the upper warning threshold. Chassis power level current is greater than the upper critical threshold. Chassis power level current is outside of range. The watchdog timer expired. The watchdog timer reset the system. The watchdog timer powered off the system. The watchdog timer power cycled the system. The watchdog timer interrupt was initiated. The BIOS watchdog timer reset the system. The OS watchdog timer reset the system. The OS watchdog timer shutdown the system.
The OS watchdog timer powered down the system. The OS watchdog timer power-cycled the system. The operating system watchdog timer powered off the system. The watchdog timer pre-timeout interrupt was initiated. The system board battery is low. Check system fans. Replace the system board battery. The system board battery has failed. Check battery. The system board battery is either missing or bad. The system board battery is absent. Reinstall the system board battery.
The storage battery is low. System has to remain powered on to charge the battery. The storage battery has failed. Verify the cable connection between the storage battery and the controller. Verify the storage battery installation. System has to remain powered on to charge the storage battery. Unsupported backplane configuration. Check CPU heat sink. The processor temperature increased beyond the operational range. System is unable to boot or may run in a degraded state.
Review the technical specifcations for supported processor types. If unexpected, check presence, and system setup BIOS configuration. The CPU is throttled due to thermal or power conditions. Review system logs for power or thermal exceptions. Check CPU.
Verify processor installation. If present, re-seat the processor. Check system operating environment. Check system operating environment, fans, and heat-sinks. Check fans. System BIOS was unable to initialize the processor. CPU bus parity error detected. CPU bus initialization error detected. System performance may be degraded or the system may fail to operate. Review this manual for proper configuration and installation procedures.
Check module. If removal was unintended, check presence and reinstall. Check hardware. Reinstall or reconnect the hardware. If device disabled unexpectedly, re-enable device. The storage adapter is absent. Install storage adapter. The storage adapter is disabled. If adapter disabled unexpectedly, re-enable the storage adapter.
The backplane is absent. If removal was unintended, check presence, then reinstall or reconnect. The backplane is disabled. If disabled unexpectedly, re-enable backplane. Check connection. Check presence, then re-install or reconnect. The fabric type for the IOM and mezzanine cards must match. Riser board cable or interconnect failure. Check the riser board or interconnect presence, then reinstall or reconnect.
If removal was unintended, check presence of the server, then reinsert. If removal was unintended, check presence of the IO module, then reinsert.
Update firmware. Hardware unsuccessfully updated for embedded NIC. Link Tuning error detected. If unexpected, check presence, then reinstall or reconnect. The fabric type for IOM's on the same chassis fabric must match. Link tuning table not supported for this IO modular.
The IOM module performance may be impacted. Information and status from the controller is unavailable. Review System Log or front panel for additional information.
CMC has lost network connection. Check network cable and network connections. This is an early indicator of a possible future uncorrectable error. Unsupported memory configuration. System performance is degraded. If unexpected, review system logs for power or thermal exceptions. Memory sparing is no longer available. Memory redundancy is lost. Memory redundancy is degraded. A hardware mismatch detected for memory riser. Memory riser mismatch detected. Check memory riser.
Memory riser is installed incorrectly, or failed. Errors are being corrected but no longer logged. A critical stop occurred during OS load. Review operating system logs and system video for additional information. A runtime critical stop occurred. A soft shut-down initiated by platform event filter.
Agent is not responding. Failed to boot from A. Failed to boot from C. Diagnostic boot failed. Failed to boot from ROM. Reboot the system and update the component drivers. System performance may be degraded, or system may fail to operate.
Re-seat PCI card. Cycle input power, update component drivers, remove and reinstall the device. Reset the system, if the problem persists reinstall processors.
The controller detected a failure on the disk and has taken the disk offline. The drive will need replacement at the next service window. The controller detected a drive removal. The controller detected that the drive was removed. Verify that the disk meets the array requirements. No memory is detected. Inspect memory devices. System BIOS was unable to detect memory in the system. Memory is detected, but is not configurable. Check memory devices. Memory is configured, but not usable.
System BIOS shadow failed. Memory errors occurred copying BIOS image into system memory. CMOS failed. DMA controller failed. Interrupt controller failed. Timer refresh failed. Power cycle system.. Programmable interval timer error. Parity error. System BIOS detected a parity error during post.
SuperIO failure. Keyboard controller failed. System management interrupt initialization failed. SMI initialization failed.
System BIOS failed to initialize the system management interrupt. Memory initialization error. BIOS Memory testing failed. Shut-down test failed. Remote access controller configuration failed. Check screen message. CPU configuration failed. Incorrect memory configuration. Review User Guide.
System BIOS detected an invalid memory population. Reinstall memory to match supported memory configuration. General failure after video. Check system video and review event log for additional information. POST fatal error detected. Check PSU. System performance and power redundancy may be degraded or lost.
Power supplies should be of the same input type and power rating. The system does not support mixed voltage power supplies. Install a power supply with the correct voltage rating. The supply has been removed or has failed. Re-seat PSU. Power supply redundancy is lost. Power supply redundancy is degraded. Remove input power and reinstall supply at the next service window.
Lost PSU redundancy. PSU redundancy degraded. The system performance was degraded. System performance degraded. Check PSUs and system configuration. To avoid shutdown, system performance has been degraded. The system performance degraded because of thermal protection. The system performance degraded because cooling capacity has changed.
The system performance degraded because power capacity has changed. The system may power down or operate in a performance degraded state. The user-defined power settings have affected system operation. If unintended, review system configuration changes and power policy. The system halted because system power exceeds capacity.
System power demand exceeds capacity. System halted. The system performance degraded because power exceeds capacity. If unintended, reinstall the flash media and module. Wait for the media to be ready.
If unintended, reinstall the flash media. An error was reported during a SD card read or write. Reseat the flash media, if the issue persists replace the media. If unintended, remove the media and disable write protection. The SD card is not detected or not installed. Removable Flash Media is ready. Removable Flash Media is not ready.
Removable Flash Media is offline. Failure detected on Removable Flash Media. An error is reported during a SD card read or write. Reinstall the flash media, if the issue persists replace the media. Removable Flash Media is write protected. Media not present for Removable Flash Media. Internal Dual SD Module redundancy is lost. Either one of the SD card or both the SD cards are not functioning properly. Replace the failed SD card. Internal Dual SD Module redundancy is degraded.
Review this manual and SD card configuration. The SD card module is not detected or not installed. If unintended, reinstall the SD module. Reinstall the SD module. Reinstall the SD module and remove and reinstall SD cards.
The module is write-protected. Changes may not be written to the media. Intrusion detected. Check chassis cover. Close the chassis. Check system logs. Close the drive bay. Close the processor area.
The LAN is disconnected. Network performance may be degraded. If unintentional, connect network cable. Unauthorized docking is detected. The fan area is open. Close the fan area. The chassis is open while the power is on. Critical Thu May 01 Server 1 health changed to a non-recoverable state. OK Mon Feb 03 Log cleared. What are you seeing on the Blade specifically? The log you shared was for the CMC not the Blade itself.
Are there any amber lights on the Me enclosure or just on the Blade? If only the Blade, what does the Drac log show for that M? Thank you. Could you power down the server and then swap dimm B4 with other matching dimm from within the server?
Then power back on and see if the error is on the location where B4 was moved to, or if it remains on the B4 slot even with the original dimm moved. Browse Community. PowerEdge Hardware General. Turn on suggestions.
Auto-suggest helps you quickly narrow down your search results by suggesting possible matches as you type. Showing results for. Search instead for. Did you mean:.